Home> Engineering Blog> Cold Rooms
Cold Rooms

Why We Prefer Friga-Bohn Evaporators in Food Warehouses

Air throw and airflow distribution are key to stable temperature and product quality. This engineering guide explains how to select the right Friga-Bohn unit.

Friga-Bohn evaporator in a cold room

In food cold-storage logistics, wrong evaporator selection can create temperature non-uniformity and product risk. Friga-Bohn units are often selected because of their well-engineered air distribution characteristics.

This article explains with practical criteria why many refrigeration engineers prefer Friga-Bohn and how to size the unit correctly.

Air Throw: The Most Critical Parameter

Air throw is the effective distance cold airflow can travel while maintaining required temperature conditions. Large rooms need sufficient throw to avoid warm zones far from the evaporator.

Typical design target at the end of throw is low but effective air velocity that avoids dehydration and minimizes local cold spots.

Air throw - LU series
8 - 20 m
Air throw - GHN series
4 - 14 m
End-of-throw air velocity
0.2 - 0.5 m/s
Recommended TD - chilled
5 - 8 C
Recommended TD - frozen
4 - 6 C
Defrost frequency - freezing
3 - 4 cycles/day
OK
Golden design rule For wider rooms, distribute evaporators to support uniform airflow coverage instead of concentrating capacity in a single point.

Main Friga-Bohn Series and Applications

Series Temperature Range Main Application Defrost Type
LU / LU-V 0 C to +10 C Fruit and vegetable storage Air off-cycle
GHN -18 C to -5 C Meat and fish freezing Electric / hot gas
RAE / RAV -25 C to -15 C Long-term frozen storage Electric
MHID -45 C to -30 C Blast freezing and IQF lines Hot gas
GBC 0 C to +5 C Dairy and cheese storage Air / hot gas

Understanding TD and Delta-T in Selection

TD is the difference between room air temperature and refrigerant evaporating temperature. Lower TD generally supports higher room humidity, which is essential for many fresh-food applications.

Some Friga-Bohn families are optimized for lower TD operation, helping maintain product-friendly humidity targets.

!
Common sizing mistake Do not select by nominal kW only. Always evaluate capacity at actual project TD, because effective delivered duty can drop significantly at lower TD values.

Defrost Strategy: Cooling vs Freezing Rooms

In freezing rooms, frost accumulation reduces heat-transfer efficiency over time. Friga-Bohn supports multiple defrost approaches depending on operating profile.

1. Hot Gas Defrost

Fast and efficient, often preferred where downtime must be minimized and process continuity is critical.

2. Electric Defrost

Simple to implement for small and medium rooms, but requires careful cycle management to avoid extra thermal disturbance.

3. Air Off-Cycle Defrost

Applicable mostly in higher-temperature rooms where light frost can be cleared without active heating.

Unit Selection by Product Category

Product Type Required Temperature Recommended Series Target TD Room Humidity
Fresh meat 0 C to 2 C LU-V 5 C 85% - 90%
Fruits and vegetables 2 C to 8 C LU-V 5 - 6 C 90% - 95%
Dairy and cheese 2 C to 6 C GBC 6 - 7 C 80% - 88%
Frozen meat and fish -18 C GHN 5 C -
Long-term freezing -22 C to -25 C RAE 4 - 5 C -

Installation and Orientation Best Practices

Even a correctly selected unit underperforms with poor installation. Key practices include:

  • Place evaporators to support full-room airflow coverage.
  • Respect clearance from ceiling and structural obstructions.
  • Ensure proper drain pan slope and reliable defrost-water disposal.
  • Avoid placement directly above high-infiltration door zones.
  • For low-temperature rooms, protect drain lines against freezing.

Periodic Maintenance for Friga-Bohn Evaporators

Task Frequency Priority
Verify complete defrost cycle performance Weekly Critical
Check defrost water drainage from pan Weekly Critical
Clean fan blades from dust and frost deposits Monthly Important
Measure fan speed and electrical current Monthly Important
Clean coil fins with low-pressure method Every 6 months Important
Inspect drain-line heating in low-temp rooms Annually Routine
X
Caution: high-pressure coil cleaning Excessive air or water pressure can permanently bend fins and reduce heat-transfer area. Use low-pressure cleaning procedures only.
OK
Conclusion Friga-Bohn is not just a brand choice; it is a design approach based on stable airflow, controlled defrost behavior, and long-term operational reliability.

Need help selecting the right evaporator for your warehouse?

Elfarida Ice can review your thermal load and recommend the correct unit for your application.

Contact Us Now

Related Articles